3 Conductor VFD Cable with Symmetrical Grounds

XLPE Insulation and NFPA 79 Compliance

3 Conductor + 3 Symmetrical Grounds VFD cables are engineered to reduce electrical noise and improve grounding performance in variable frequency drive motor applications. This construction uses three symmetrically spaced ground conductors to minimize EMI, improve signal integrity, and protect motor bearings in demanding industrial environments.

Designed in accordance with NFPA 79 (2018), Section 4.4.2.8, these VFD cables commonly feature XLPE insulation, a low-capacitance thermoset material optimized for high switching frequencies between the VFD and motor.

3 Conductor + 3 Ground VFD Cable Types

Click desired product for more information

Product Category

Filter

Flexible 3C+ 3GND VFD Cable Series

LUTZE DRIVEFLEX® A220 (3) GND

  • Jacket: PVC, black

  • Insulation: XLPE type XHHW-2, black

  • Shielding: foil tape, overall tinned copper braid

  • Voltage: 600V / 1000V

  • Certifications: UL Flexible VFD Servo, TC-ER-JP, AWM 105C°

  • Range: AWG 6 – 500 MCM; 3C + 3GND

Elettrotek Kabel GAALFLEX® VFD 1405 (3) GND

  • Jacket: PVC, black

  • Insulation: XLPE, black

  • Shielding: aluminum tape, PETP foil and tinned copper braid

  • Voltage: 1000V

  • Certifications: UL Flexible Motor Supply, WTTC, TC-ER; CE

  • Range: AWG 10 – 500 MCM; 3C + 3GND

HELUKABEL TOPFLEX® 1000 VFD (3) GND

  • Jacket: TPE, black

  • Insulation: XLPE, black

  • Shielding: foil and tinned braid

  • Voltage: 600/1000V

  • Certifications: UL TC-ER, WTTC, FLEXIBLE MOTOR SUPPLY, CSA, CE

  • Range: AWG 8 – 500MCM;  3C + 3GND

TPC Super-Trex® VFD Cable

  • Jacket: TSE, yellow

  • Insulation: TSE, black/numbered

  • Shielding: tinned copper braid, drain wire

  • Voltage: 600V

  • Certifications: UL TC-ER

  • Range: AWG 4 – 535MCM, 3C + 3GND

Class B stranded 3C + 3GND VFD Cable Series

AmerCable 37-108VFD Tinned CU VFD

  • Jacket: PVC, black

  • Insulation: Power: XLPE, black; GND: bare

  • Shielding: copper tape

  • Voltage: 1000V

  • Certifications: UL TC-ER

  • Range: AWG 14 – 777MCM; 3C + 3GND

BELDEN VFD Basics 600V

  • Jacket: PVC, black

  • Insulation: XLPE, black and numbered

  • Shielding: dual tape

  • Voltage: 600V / 1000V

  • Certifications: UL TC-ER, AWM

  • Range: AWG 16 – 4/0 AWG; 3C+ 3GND

AmerCable 37-600VFD Bare CU VFD

  • Jacket: PVC, black

  • Insulation: Power: XLPE type XHHW-2, black; GND: bare

  • Shielding: copper tape

  • Voltage: 1000V

  • Certifications: UL TC-ER

  • Range: AWG 14 – 750MCM; 3C + 3GND

BELDEN Classic 100% VFD (3) GND

  • Jacket: PVC, black

  • Insulation: XHHW-2, black/numbered

  • Shielding: two spiral tape

  • Voltage: 1000V

  • Certifications: UL Flexible Motor Supply, WTTC, CSA AWM, TC-ER; CE

  • Range: AWG 1 – 4/0 AWG; 3C + 3GND

Next
Back to products

Class K stranding according to ASTM B174 (172), is a AWM strand count making up individual conductors. For example, a 12AWG conductor with Class K stranding will consist of 65 strands of 30AWG copper wire.