LUTZE DRIVEFLEX® 3 Grounds PVC VFD Cable, A220

Shielded with 3-Symmetrical Grounds, XLPE type RHW-2

1000V UL Flexible VFD Servo Cable, TC-ER, WTTC

LUTZE DRIVEFLEX ® A220 VFD series cables are your premium solution for power connections between larger electrical motors and Variable Frequency Drives (VFD). Recommended for motors 40HP and larger, the 3 symmetrical ground design minimizes stray currents in the motor shaft and bearings, extending the life of the motor.

Shielded construction:

Configuration: 3 Power conductors + 3 Symm. Grounds

Conductor: class K stranded tinned copper

Insulation: XLPE type XHHW-2 (3 Power + 3 Grounds)

Color code: black w/ white #s, green/yellow ground

Shielding: foil tape, tinned copper braid and drain wire

Jacket: oil resistant PVC, black

Voltage:

600V UL TC-ER

1000V Flexible VFD Servo Cable 90C

1000V WTTC

Temperature

-40°C – +90°C static

Minimum Bending Radius

7.5 x cable OD fixed

Conductor Marking

Black with white numbers and one green/yellow ground

Oil Resistance

Oil Res II

  • UL Type Flexible Motor Supply Cable up to 4/0

  • Meets NEC 336, 392 Class I & II, Div. 2 and Class I Zone 2 per NEC 501, 502, 505

  • UL Types WTTC, TC-ER

  • c(UL) TC, CIC FT4, CE

  • UL 1277, UL 2277

  • P-07-KA130021-MSHA

  • RoHS

  • REACH

  • Flexible XLPE conductors

  • Three symmetrical, insulated grounds (PEs)

  • Non-wicking fillers

  • Effective dual layer shield for best EMC results

  • Specially formulated jacket for oil resistance and easy strip design

  • Crush impact resistant

  • Gas/vapor-tight sheath per UL 1277

  • Low capacitance cable

  • Sunlight resistant

  • Flame retardant

  • Direct burial

  • Talc and Silicone free

  • 1 kV rated XLPE insulation with low capacitance, ideal for applications with high voltage spikes and long cable runs

  • Compliant with NFPA 79 for wiring of industrial machinery

  • TC-ER for use with cable trays without conduit, which can reduce material and labor costs

  • WTTC – wind turbine tray cable rating for use in wind power generation

  • Dry, damp or wet conditions

Part Number Manufacturer Description AWG # of Cond. Nom OD (in)

6AWG

A2200603 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (AWG6/3C + AWG12/3GND TC-ER, UL-VFD 1000V 6 6 0.941

4AWG

A2200403 LUTZE LUTZE DRIVEFLEX®3 SYMMETRICAL GROUND (AWG4/3C + AWG12/3GND TC-ER, UL-VFD 1000V 4 6 1.091

2AWG

A2200203 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (AWG2/3C + AWG10/3GND) TC-ER 600V, BLACK 2 6 1.154

1AWG

A2200103 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (AWG1/3C + AWG8/3GND TC-ER, UL-VFD 1000V 1 6 1.386

1/0

A2201/003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (1/0/3C + AWG8/3GND) TC-ER, UL-VFD 1000V, BLACK 1/0 6 1.461

2/0

A2202/003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (2/0/3C + AWG8/3GND) TC-ER, UL-VFD 1000V, BLACK 2/0 6 1.539

3/0

A2203/003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (3/0/3C + AWG6/3GND) TC-ER, UL-VFD 1000V, BLACK 3/0 6 1.630

4/0

A2204/003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (4/0/3C + AWG6/3GND) TC-ER, UL-VFD 1000V, BLACK 4/0 6 1.882

250 MCM

A22025003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (250 MCM/3c + AWG6/3GND) TC-ER 600V, BLACK 250 6 2.031

350 MCM

A22035003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (350 MCM/3C + AWG4/3GND) TC-ER 600V, BLACK 350 6 2.339

500 MCM

A22050003 LUTZE LUTZE DRIVEFLEX® 3 SYMMETRICAL GROUND (500 MCM/3C + AWG4/3GND) TC-ER 600V, BLACK 500 6 2.591