VFD Cable:

4 Conductor + 1 Signal Pair

VFD Cables with 4 conductors + 1 signal pair exist to simplify installation where power and signal are needed in one cable. Designed with XLPE insulation per NFPA 79 2018 article 4.4.2.8, which suggests the use of XLPE insulation, a low capacitance, thermoset insulation between your VFD and motor. For VFD cables with 2 signal pairs, see 4 Conductor + 2 Signal Pairs VFD Cables

4 Conductor + 1 Signal Pair VFD Cable Series

BELDEN Classic 300% VFD with Signal Pair

  • Jacket: PVC, black

  • Insulation: XLPO, black/numbered

  • Shielding: foil and tinned copper braid

  • Voltage: 600V / 1000V

  • Certifications: 1000V UL Flexible Motor Supply, WTTC, CSA AWM, 600V TC-ER; CE

  • Range: AWG 14 – 2 AWG up to 4 conductors

Elettrotek Kabel GAALFLEX® VFD 1405 with (1) signal pair

  • Jacket: special PVC, black

  • Insulation: XLPE, black

  • Shielding: aluminum tape, PETP foil and overall tinned copper braid (same for pairs)

  • Voltage: 600V / 1000V

  • Certifications: 1000V UL Flexible Motor Supply, WTTC, 600V TC-ER, CE

  • Range: AWG 14 – 2/0; (4) conductors plus 1 pair

LAPP OLFLEX® VFD with Signal

  • Jacket: TPE, black

  • Insulation: “Lapp Surge Guard”, black

  • Shielding: foil and braid

  • Voltage: 600/1000

  • Certifications: UL TC-ER, MTW, WTTC, AWM, CSA, CE

  • Range: AWG 1 -500MCM;  3C + 3GND

LUTZE DRIVEFLEX®  A107 with (1) signal pair

  • Jacket: PVC, black

  • Insulation: XHHW-2, black

  • Shielding: foil tape, overall tinned copper braid (foil for pairs)

  • Voltage: 600V / 1000V

  • Certifications: UL Flexible Motor Supply, TC-ER, CSA

  • Range: AWG 16 – 10, (4) conductors plus 1 pair

LUTZE DRIVEFLEX® A217 with (1) signal pair

  • Jacket: PVC, black

  • Insulation: RHW-2, black

  • Shielding: foil tape, overall tinned copper braid (foil for pairs)

  • Voltage: 600V / 1000V

  • Certifications: UL Flexible VFD Servo, 600V TC-ER-JP, AWM 105C°

  • Range: AWG 16 – 2; (4) conductor plus 1 pair

HELUKABEL TOPFLEX® 650 VFD w/ control pairs

  • Jacket: TPE, black

  • Insulation: XLPE, black

  • Shielding: foil and tinned braid

  • Voltage: 600/1000V

  • Certifications: UL TC-ER, WTTC, FLEXIBLE MOTOR SUPPLY, CSA, CE

  • Range: AWG 16 – 4; (4) conductor plus 1 pair

SAB VFD Combo XLPE

  • Jacket: copolymer, black

  • Insulation: crosslinked PE, black/numbered

  • Shielding: foil and tinned copper braid

  • Voltage: 600V / 1000V

  • Certifications: UL TC-ER, WTTC, AWM, CSA, CE

  • Range: AWG 16 – 2 AWG up to 4 conductors + 1TSP

Southwire SPEC 45441 CU 600V RHW-2 TPE VFD

  • Jacket: TPE, black

  • Insulation: RHW-2, black/numbered

  • Shielding: foil, tinned copper braid, drain wire

  • Voltage: 600/1000V

  • Certifications: UL TC-ER, Flexible Motor Supply, CSA, CE

  • Range: AWG 16 – 6 AWG; 4C plus one shielded pair