Electronic Instrumentation Cables
Color coded multi-conductor, pair and triad cables
Electronic and Instrumentation Cable describes a 300V multi-conductor, multi-paired or multi-triad cable used for low voltage signal transmission and monitoring of machinery and equipment critical to the production process. This type of cable is typically available in sizes 22AWG to 12AWG with color coded conductors, overall shielded and/or individually shielded and unshielded in both flexible and continuous flexing constructions. Approvals can range from UL Listed Power Limited Tray Cable (PLTC), Communication (type CM), Instrumentation Tray Cable (ITC) or UL recognized as Appliance Wiring Material (AWM).
Types
Flexible MULTI-CONDUCTOR Series UNSHIELDED
LUTZE ELECTRONIC PLTC A303
-
Jacket: PVC, gray
-
Insulation: SR-PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC 105°C, AWM
-
Range: AWG 22 -16; up to 25 conductors
-
Spec Sheet
LAPP UNITRONIC® 300
-
Jacket: PVC, gray
-
Insulation: special PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL CMG, PLTC, PLTC-ER, ITC-ER, AWM
-
Range: AWG 24 -16; up to 25 conductors
-
Spec Sheet
HELUKABEL TRAYCONTROL® 300
-
Jacket: PVC, gray
-
Insulation: special PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC-ER, ITC-ER, AWM 2517, CM; CSA
-
Range: AWG 28 -16; up to 50 conductors
-
Spec Sheet
SAB DC 105 PLTC
-
Jacket: PVC, gray
-
Insulation: semi-rigid PVC (AWG26-20), color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC, PLTC-ER, ITC-ER, CMG; CSA, CE
-
Range: AWG 26 -16; up to 50 conductors
-
Spec Sheet
ALPHA Xtra-Guard® 1 Multiconductor
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CM, MTW, CSA
-
Range: AWG 28 -16; up to 50 conductors
-
Spec Sheet
ALPHA Xtra-Guard® 2 Multiconductor
-
Jacket: PUR, black
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CSA
-
Range: AWG 24 -16; up to 70 conductors
-
Spec Sheet
BELDEN MACHFLEX® 360TC CONTROL
-
Jacket: TPE, gray
-
Insulation: PVC, black and numbered
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC, AWM; CSA, CE
-
Range: AWG 20; up to 24 conductors
-
Spec Sheet
ALPHA Series P PLTC TPE
-
Jacket: TPE, gray
-
Insulation: PVC/Nylon, black and numbered
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC, CSA, CE
-
Range: AWG 18 -12; up to 65 conductors
-
Spec Sheet
Flexible MULTI-CONDUCTOR Series SHIELDED
LUTZE Electronic PVC, A313
-
Jacket: PVC, gray
-
Insulation: SR-PVC, color coded
-
Shielding: Foil, Braid, Drain wire
-
Voltage: 300V
-
Certifications: UL PLTC, AWM 2464
-
Range: AWG 22 -16; up to 25 conductors
-
Spec Sheet
LAPP UNITRONIC® 300 S
-
Jacket: PVC, gray
-
Insulation: special PVC, color coded
-
Shielding: Foil, Braid
-
Voltage: 300V
-
Certifications: UL CMG, PLTC, PLTC-ER, ITC-ER, AWM
-
Range: AWG 24 -16; up to 25 conductors
-
Spec Sheet
HELUKABEL TRAYCONTROL® 300-C
-
Jacket: PVC, gray
-
Insulation: special PVC, color coded
-
Shielding: Foil, Braid
-
Voltage: 300V
-
Certifications: UL PLTC-ER, ITC-ER, AWM 2517, CM; CSA
-
Range: AWG 28 -16; up to 50 conductors
-
Spec Sheet
SAB DC 105 PLTC
-
Jacket: PVC, gray
-
Insulation: semi-rigid PVC (AWG26-20), color coded
-
Shielding: Foil, Braid, Drain Wire
-
Voltage: 300V
-
Certifications: UL PLTC (22-20AWG), PLTC-ER, ITC-ER (18-16AWG), CMG; CSA, CE
-
Range: AWG 26 -16; up to 50 conductors
-
Spec Sheet
BELDEN MACHFLEX® SUPER 360TC
-
Jacket: TPE, gray
-
Insulation: PVC, black and numbered
-
Shielding: Shielded
-
Voltage: 300V
-
Certifications: UL PLTC, AWM; CSA, CE
-
Range: AWG 20; up to 25 conductors
-
Spec Sheet
ALPHA Xtra-Guard® 1 Supra-Shield®
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CM, MTW, CSA
-
Range: AWG 28 -16; up to 50 conductors
-
Spec Sheet
Flexible MULTI-PAIR Series UNSHIELDED
BELDEN UL INSTRUMENTATION PLTC
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC, ITC, AWM 2464, CMG; CE
-
Range: AWG 22 – 16; 1 pair
-
Spec Sheet
ALPHA Xtra-Guard® 1 Multipair PVC
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CM, CSA
-
Range: AWG 24 -18; up to 15 pairs
-
Spec Sheet
BELDEN UL INSTRUMENTATION, PAIRS
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CMG
-
Range: AWG 24 – 20; up to 27 pairs
-
Spec Sheet
Flexible MULTI-PAIR Series SHIELDED
LUTZE Electronic, PAIRS
-
Jacket: PVC, gray
-
Insulation: SR-PVC, color coded
-
Shielding: Foil, Braid, Drain wire
-
Voltage: 300V
-
Certifications: UL PLTC, AWM 2464
-
Range: AWG 22 – 16; up to 8 pairs
-
Spec Sheet
SAB DC 105 TP, PAIRS
-
Jacket: PVC, gray
-
Insulation: semi-rigid PVC (AWG24-20), color coded
-
Shielding: Foil, Braid, Drain Wire
-
Voltage: 300V
-
Certifications: UL PLTC (22-20AWG), PLTC-ER, ITC-ER (18-16AWG), CMG; CSA, CE
-
Range: AWG 24 -16; up to 15 pairs
-
Spec Sheet
LAPP UNITRONIC® 300 STP
-
Jacket: PVC, gray
-
Insulation: special PVC, color coded
-
Shielding: Foil, Braid
-
Voltage: 300V
-
Certifications: UL PLTC-ER, ITC-ER, CMG, AWM 2464; CSA, CE
-
Range: AWG 24 -16; up to 15 pairs
-
Spec Sheet
BELDEN UL INSTRUMENTATION, PAIRS
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: TSP and/or Overall shield
-
Voltage: 300V
-
Certifications: UL PLTC, ITC, AWM 2464, CMG; CE
-
Range: AWG 22 – 16; 1 pair
-
Spec Sheet
ADC TYPE PLTC PAIRS
-
Jacket: PVC, black
-
Insulation: PVC, color coded (black/white)
-
Shielding: overall shielded
-
Voltage: 300V
-
Certifications: UL PLTC, ITC
-
Range: AWG 20 – 16; up to 16 pairs
-
Spec Sheet
ADC TYPE PLTC SHIELDED PAIRS
-
Jacket: PVC, black
-
Insulation: PVC, color coded (black/white)
-
Shielding: TSP + Overall shield
-
Voltage: 300V
-
Certifications: UL PLTC, ITC
-
Range: AWG 20 – 16; up to 16 pairs
-
Spec Sheet
BELDEN UL INSTRUMENTATION SHIELDED PAIRS + OVERALL
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: TSP + Overall shield
-
Voltage: 300V
-
Certifications: UL PLTC, ITC
-
Range: AWG 22 – 16; up to 19 pairs
-
Spec Sheet
ALPHA Xtra-Guard® 1 Multipair PVC
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CM, CSA
-
Range: AWG 28 -18; up to 51 pairs
-
Spec Sheet
Flexible MULTI-TRIAD Series UNSHIELDED
BELDEN UL 300V PLTC, TRIADS
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC, ITC, AWM, CMG; CE
-
Range: AWG 22 – 16; 1 triad
-
Spec Sheet
Flexible MULTI-TRIAD Series SHIELDED
BELDEN UL 300V PLTC, TRIADS
-
Jacket: PVC, black
-
Insulation: PVC, color coded
-
Shielding: TSP and/or overall foil shield
-
Voltage: 300V
-
Certifications: UL PLTC, ITC, AWM, CMG; CE
-
Range: AWG 22 – 16; up to 36 triads
-
Spec Sheet
ADC TYPE PLTC TRIADS
-
Jacket: PVC, black
-
Insulation: PVC, color coded (black/white)
-
Shielding: TSP + overall foil shield + drain wire
-
Voltage: 300V
-
Certifications: UL PLTC, ITC
-
Range: AWG 20 – 16; up to 16 pairs
-
Spec Sheet
High Flex MULTI-CONDUCTOR Series UNSHIELDED
BELDEN MACHFLEX® SUPER 360TC
-
Jacket: TPE, orange
-
Insulation: PVC, black and numbered
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL PLTC, AWM; CE
-
Range: AWG 20 – 16; up to 24 conductor
-
Spec Sheet
LUTZE SUPERFLEX® TRONIC PUR
-
Jacket: PUR, gray
-
Insulation: TPE insulation, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM 20549
-
Range: AWG 24-22; up to 25 conductors
-
Spec Sheet
SAB SD 960 P
-
Jacket: PUR, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CSA, CE
-
Range: AWG 26 -22; up to 25 conductors
-
Spec Sheet
ALPHA Xtra-Guard® Continuous Flex Data
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM, CM, CSA
-
Range: AWG 28 -22; up to 25 conductors
-
Spec Sheet
LUTZE SUPERFLEX® TRONIC AS PUR
-
Jacket: PUR, black
-
Insulation: TPE, color coded
-
Shielding: Unshielded
-
Voltage: 300V
-
Certifications: UL AWM 20549
-
Range: AWG 22; up to 18 conductors
-
Spec Sheet
High Flex MULTI-CONDUCTOR Series SHIELDED
LUTZE SUPERFLEX® TRONIC PUR
-
Jacket: PUR, matte gray
-
Insulation: TPE, DIN 47100 color code
-
Shielding: tinned copper braid
-
Voltage: 300V
-
Certifications: UL AWM
-
Range: AWG 26 – 22; up to 25 conductors
-
Spec Sheet
LUTZE SUPERFLEX® TRONIC AS PUR
-
Jacket: PUR, black
-
Insulation: TPE, color code per EN 60947-5-2
-
Shielding: tinned copper braid
-
Voltage: 300V
-
Certifications: UL AWM
-
Range: AWG 22; up to 5 conductors
-
Spec Sheet
BELDEN MACHFLEX® SUPER 360TC, PLTC
-
Jacket: TPE, orange
-
Insulation: PVC, black and numbered
-
Shielding: tinned copper braid
-
Voltage: 300V
-
Certifications: UL PLTC, AWM; CE
-
Range: AWG 20 – 16; up to 24 conductor
-
Spec Sheet
High Flex MULTI-PAIR Series SHIELDED
LUTZE SUPERFLEX® TRONIC PUR TP
-
Jacket: PUR, gray
-
Insulation: TPE, DIN 47100 color code
-
Shielding: tinned copper braid
-
Voltage: 300V UL AWM
-
Certifications: UL AWM 20549, CE
-
Range: AWG 24 -19; up to 12 pairs
-
Spec Sheet
ELETTROTEK FLEXIDRUM® 210 C TP
-
Jacket: PUR, gray
-
Insulation: TPE, DIN 47100 color code
-
Shielding: tinned copper braid
-
Voltage: 300V
-
Certifications: UL AWM 21198, CSA
-
Range: AWG 26 -16; up to 25 pairs
-
Spec Sheet
SAB SD 960 CY TP
-
Jacket: PVC, black
-
Insulation: PVC, color coded
-
Shielding: braid shield
-
Voltage: 300V
-
Certifications: UL AWM; CE
-
Range: AWG 26 -20; up to 25 pairs
-
Spec Sheet
SAB SD 960 CP TP
-
Jacket: PUR, gray
-
Insulation: PVC, color coded
-
Shielding: foil + braid shield + drain wire
-
Voltage: 300V
-
Certifications: UL AWM, CSA, CE
-
Range: AWG 26 -19; up to 25 pairs
-
Spec Sheet
IGUS CHAINFLEX® CF211
-
Jacket: PVC, gray
-
Insulation: TPE, color coded
-
Shielding: tinned copper braid
-
Voltage: 300V
-
Certifications: UL AWM, CE
-
Range: AWG 24 -20; up to 14 pairs
-
Spec Sheet
ALPHA Xtra-Guard® Continuous Flex Data
-
Jacket: PVC, gray
-
Insulation: PVC, color coded
-
Shielding: foil + braid shield
-
Voltage: 300V
-
Certifications: UL AWM, CM, CSA
-
Range: AWG 28 -22; up to 25 conductors
-
Spec Sheet
Thermocouple Cables
BELDEN THERMOCOUPLE EXTENSION
-
Jacket: PVC or FEP
-
Insulation: PVC or FEP, color coded
-
Shielding: unshielded
-
Temp: 105°C – 200°C
-
Certifications: UL PLTC, ITC, CMG
-
Range: AWG 20 – 16; up to 8 pairs
-
Spec Sheet
Search ALL Electronic Instrumentation Cable Configurations
Need a quote? Select desired configuration(s), Enter Quantity & click +Add to Inquiry
Request A Quote
Build your Quote Cart as you browse our online catalog or send us your application requirements, and we'll provide tailored product options that fit your needs.
Looking for in-stock products? Through our trusted partnerships, we have direct access to over 45 stocking warehouses across North America - with cut-to-length and same day shipping available. Request your quote today!