VNTC Class B Tray Cables are the most common and economical type of tray rated cable used in a variety of applications from residential to industrial. Typical characteristics of this cable include the Vinyl Nylon coated THHN or THWN insulated conductors, unshielded and made with class B stranding, making it a cost effective choice for power distribution or when flexibility is not a priority. These cables can be rated UL TC and TC-ER in both 300V and 600V. Don’t need a tray rating? See our portfolio of Flexible Power and Control Cables.

Class B Stranded Tray Cable Series

BELDEN UL Control Cable

  • Jacket: PVC, black

  • Insulation: PVC/Nylon, black and numbered

  • Shielding: Unshielded

  • Voltage: 600V

  • Certifications: UL TC-ER

  • Range: AWG 18 – 4/0;  up to 50 conductors

  • Spec Sheet

Southwire 3/C CU 600V PVC THHN Power

  • Jacket: PVC, black

  • Insulation: PVC/Nylon, black and numbered

  • Shielding: Unshielded

  • Voltage: 600V

  • Certifications: UL TC-ER

  • Range: AWG 8 – 750MCM;  3C + 1 reduced GND

  • Spec Sheet

General Cable VNTC®

  • Jacket: PVC, black

  • Insulation: PVC/Nylon, black and numbered

  • Shielding: Unshielded

  • Voltage: 600V

  • Certifications: UL TC-ER

  • Range: AWG 14 – 10;  up to 37 conductors

  • Spec Sheet

Southwire CU 600V PVC Control

  • Jacket: PVC, black

  • Insulation: PVC/Nylon, color coded

  • Shielding: Unshielded

  • Voltage: 600V

  • Certifications: UL TC-ER

  • Range: AWG 8 – 750MCM;  3C + 1 reduced GND

  • Spec Sheet

Lapp OLFLEX® TRAY VTC

  • Jacket: PVC, black

  • Insulation: PVC, black and numbered

  • Shielding: Unshielded

  • Voltage: 600/1000V

  • Certifications: UL TC-ER, AWM, WTTC

  • Range: AWG 18 – 6;  up to 25 conductors

  • Spec Sheet

BELDEN UL Control Cable Shielded

  • Jacket: PVC, black

  • Insulation: PVC/Nylon, black and numbered

  • Shielding: Foil

  • Voltage: 600V

  • Certifications: UL TC-ER

  • Range: AWG 18 – 14;  up to 4 conductors

  • Spec Sheet

ADC Type TC-ER Control & Power Tray Cable

  • Jacket: PVC, black

  • Insulation: special PVC/Nylon

  • Shielding: Unshielded

  • Voltage: 600V

  • Certifications: UL TC-ER-JP

  • Range: AWG 8 – 500MCM;  up to 4 conductors

  • Spec Sheet

ADC Type TC-ER Control & Power Tray Cable

  • Jacket: PVC, black

  • Insulation: special PVC/Nylon

  • Shielding: overall aluminum foil + drain wire

  • Voltage: 600V

  • Certifications: UL TC-ER-JP

  • Range: AWG 18 – 10;  up to 25 conductors