LUTZE DRIVEFLEX® XLPE PVC VFD w/ signal, A107
Shielded with (1) Control Pair
1000V UL Flexible VFD Servo Cable, WTTC, 600V TC-ER
LUTZE DRIVEFLEX ® A107 VFD cable series is your solution for power and signal connections between electric motors and Variable Frequency Drives (VFD). DRIVEFLEX® A107 includes a single shielded, twisted control pair along with (3) power conductors and (1) ground, XLPE insulation and black PVC jacket. Meets NFPA 79 2018 article 4.4.2.8
Shielded construction:
Configuration: 3 Power conductors + GND + 1 TSP
Conductor: class K stranded tinned copper
Insulation: XLPE type XHHW-2 (A1071404R – pairs: THHN)
Color code: black w/ white #s, green/yellow ground
Shielding: foil tape, tinned copper braid and braid wire
Jacket: oil resistant PVC, black
Voltage
600V UL TC-ER-JP
1000V Flexible VFD Servo Cable
90C, 1000V 105C AWM
1000V WTTC
Temperature
-40°C – +90°C static
Bending Radius
6 x cable OD
Oil Resistance
Oil Res II
-
UL Type Flexible Motor Supply Cable
-
UL Type Flexible VFD Servo Cable
-
TC-ER-JP
-
WTTC
-
DP-1
-
Meets NEC 336, 392 Class I & II, Div. 2 and Class I Zone 2 per NEC 501, 502, 505
-
AWM 20886
-
c(UL) TC, CIC FT4
-
UL 1277
-
RoHS
-
REACH
-
Shielded motor supply cable to connect power to 3-phase motors, VFD’s and Servo Drives
-
Cable design for harsh industrial environments and operating conditions with high noise levels
-
Thermoset XLPE offering superior overload and short-circuit temperature
-
Type XHHW-2 insulation offering smaller ODs for general VFD applications
-
Compliant with NFPA 79 for wiring of industrial machinery
-
TC-ER-JP for use with cable trays without conduit, which can reduce installation costs in industrial environments per NEC 336.10 (7)
-
WTTC – wind turbine tray cable rating for use in wind power generation
-
Dry, damp or wet conditions
-
Flexible XLPE conductor design
-
Reduced cable OD’s
-
High insulation resistance
-
Low capacitance cable
-
Effective dual layer shield for EMC compliance
-
Specially formulated jacket for oil resistance and easy strip
-
Crush impact resistant
-
Gas/vapor-tight sheath per UL 1277
-
Sunlight resistant
-
Flame retardant
-
Direct burial
-
Talc and Silicone free
DRIVEFLEX® A107 – Power + Signal
| Part Number | Manufacturer | Description | AWG | # of Cond. | Nom OD (in) |
|---|---|---|---|---|---|
18AWG |
|||||
| A1071804 | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG18/4C PLUS 1 PAIR AWG18 UL TC/CE | 16 | 6 | 0.476 |
16AWG |
|||||
| A1071604 | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG16/4C PLUS 1 PAIR AWG18 UL TC/CE | 16 | 6 | 0.520 |
14AWG |
|||||
| A1071404 | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG14/4C PLUS 1 PAIR AWG16 UL TC/CE | 14 | 6 | 0.583 |
14AWG - Reduced OD |
|||||
| A1071404R | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG14/4C PLUS 1 PAIR AWG18 THHN | 14 | 6 | 0.512 |
12AWG |
|||||
| A1071204 | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG12/4C PLUS 1 PAIR AWG16 UL TC/CE | 12 | 6 | 0.618 |
10AWG |
|||||
| A1071004 | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG10/4C PLUS 1 PAIR AWG14 UL TC/CE | 10 | 6 | 0.720 |
8AWG |
|||||
| A1070804 | LUTZE | LUTZE DRIVEFLEX® XLPE XHHW-2 AWG08/4C PLUS 1 PAIR AWG14 UL TC/CE | 8 | 6 | 0.945 |