LUTZE DRIVEFLEX® XLPE, 2TSP, PVC, VFD, A218
Shielded VFD cable with (2) twisted shielded control pairs (TSP)
1000V UL Flexible VFD Servo Cable, WTTC, 600V TC-ER


LUTZE DRIVEFLEX® XLPE PVC VFD A218 series cable is your solution for power and multiple signal connections between electric motors and Variable Frequency Drives (VFD). The A218 series includes (2) twisted shielded control pairs along with power conductors using RHW-2 thick wall XLPE insulation, ideal for larger motors, drives and long cable runs. Meets NFPA 79 2018 article 4.4.2.8
Shielded construction:
Configuration: 3 Power conductors + GND + 2 TSP
Conductor: class K stranded tinned copper
Insulation: XLPE type RHW-2 (2-pairs XHHW-2)
Color code: black w/ white #s, green/yellow ground
Shielding: foil tape, tinned copper braid and drain wire
Jacket: oil resistant PVC, black

Voltage
600V UL TC-ER-JP
1000V Flexible VFD Servo
Cable 90C, 1000V 105C AWM
1000V WTTC
Temperature
-40°C – +90°C static
Minimum Bending Radius
6 x cable OD
Oil Resistance
Oil Res II
-
UL Type Flexible Motor Supply Cable
-
UL Type Flexible VFD Servo Cable
-
TC-ER-JP, WTTC, DP-1
-
Meets NEC 336, 392 Class I & II, Div. 2 and Class I Zone 2 per NEC 501, 502, 505
-
AWM 20886
-
c(UL) TC, CIC FT4
-
UL 1277
-
P-07-KA130021-MSHA
-
RoHS
-
REACH
-
Shielded multi-conductor cable for VFD, Servo and Motor applications to connect power from drives to motors
-
Cable design for harsh industrial environments and operating conditions with high noise levels
-
XLPE thick wall insulation with low capacitance, ideal for applications with high voltage spikes and long cable runs
-
Compliant with NFPA 79 for wiring of industrial machinery
-
TC-ER-JP for use with cable trays without conduit, which can reduce material and labor costs
-
WTTC – wind turbine tray cable rating for use in wind power generation
-
Dry, damp or wet conditions
-
Flexible XLPE conductor design
-
Non-wicking fillers
-
Effective dual layer shield for EMC compliance
-
Specially formulated jacket for oil resistance and easy strip design
-
Crush impact resistant
-
Gas/vapor-tight sheath per UL 1277
-
Low capacitance cable
-
Sunlight resistant
-
Flame retardant
-
Direct burial
-
UL Type TC-Exposed Run-Joist Pull
-
Talc and Silicone free
Part Number | Manufacturer | Description | AWG | # of Cond. | Nom OD (in) |
---|---|---|---|---|---|
16AWG |
|||||
A2181604 | LUTZE | LUTZE DRIVEFLEX® N (C) SERVO II (AWG16/4C + 2TSP AWG18), BLACK | 16 | 8 | 0.701 |
14AWG |
|||||
A2181404 | LUTZE | LUTZE DRIVEFLEX® N (C) SERVO II (AWG14/4C + 2TSP AWG16), BLACK | 14 | 8 | 0.760 |
12AWG |
|||||
A2181204 | LUTZE | LUTZE DRIVEFLEX® N (C) SERVO II (AWG12/4C + 2TSP AWG16), BLACK | 12 | 8 | 0.795 |
10AWG |
|||||
A2181004 | LUTZE | LUTZE DRIVEFLEX® N (C) SERVO II (AWG10/4C + 2TSP AWG14), BLACK | 10 | 8 | 0.929 |
8AWG |
|||||
A2180804 | LUTZE | LUTZE DRIVEFLEX® N (C) SERVO II (AWG8/4C + 2TSP AWG14), BLACK | 8 | 8 | 1.071 |